Description
## Features
- The FloTech thermo-optic 2 wire probe is electronically and mechanically compatible for drop-in replacement of other commonly used 2-wire probes with black and white wires. Providing the fast response and reliability of optic technology in a thermistor application.
- 12" black and white 2 wire overfill detection probe
- The sensor housing contains a black and white 2 wire probe in a cast aluminum housing. The sensor housing has a 2" NPT mounting thread, heavy duty stainless steel hardware, and FKM probe seal.
## Installation
Install into either a 2" NPT threaded port or 2-3/8" diameter tank opening using the gasket and locking nut provided.
## Includes
12" probe
## Note
All FloTech™ electronics manufactured after January 1, 2015 are covered by our 5 year warranty.
## Use
Overfill Only
## Prop 65 Warning
**WARNING**: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.
Specifications
| Weight | 1.71 lb |
|---|---|
| Break Quantity | 1 |
| Optional Package/Box Quantity | 1 |
| Fuel Compatability | Gasoline, Diesel, USLD, Crude Oil, E10, E20, E85, E100, B2, B20, B100 |
| Features | The FloTech thermo-optic 2 wire probe is electronically and mechanically compatible for drop-in replacement of other commonly used 2-wire probes with black and white wires. Providing the fast response and reliability of optic technology in a thermistor application. 12" black and white 2 wire overfill detection probe The sensor housing contains a black and white 2 wire probe in a cast aluminum housing. The sensor housing has a 2" NPT mounting thread, heavy duty stainless steel hardware, and FKM probe seal. |
| Installation | Install into either a 2" NPT threaded port or 2-3/8" diameter tank opening using the gasket and locking nut provided. |
| Includes | 12" probe |
| Note | All FloTech™ electronics manufactured after January 1, 2015 are covered by our 5 year warranty. |
| Use | Overfill Only |
| Prop 65 Warning | WARNING : This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. |
PDF Documents
2 Wire System - Black and White Wires revised.pdf
Open PDF
10159_Dec_2008_Thermo_Optic_Sensors_CANMIS_1290787511.pdf
Open PDF
10234_FT520_EN_FR_CANMIS_1318853818.pdf
Open PDF
10236_REVB_Probe_cutting_EN_FR_CANMIS.pdf
Open PDF
10784PA_REV_C_FT555___EN_FR__051214_CANMIS.pdf
Open PDF
10784PA_REV_C_FT555F_EN_FR_051214_CANMIS.pdf
Open PDF
10236 Sensor Tube Cutting Instructions.pdf
Open PDF
184.pdf
Open PDF
2024 Dixon Bayco® Petroleum and Overfill Catalog
Open PDF
2-Wire and 5-Wire Aviation Fuel Truck Packages
Open PDF