    "data": {
        "id": 7753,
        "sku": "wilkerson-frls-m16-series-compact-coalescing-filter/m16-04m",
        "name": "M16-04M - Wilkerson FRLs M16-Series Compact Coalescing Filter",
        "type": "simple",
        "variations_count": 0,
        "manufacturer": "Dixon Valve",
        "product_url": "https://dixonvalve.com/en/products/wilkerson-frls-m16-series-compact-coalescing-filter/m16-04m",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 174,
            "name": "wilkerson-frls-m16-series-compact-coalescing-filter"
        },
        "categories": [
            {
                "id": 174,
                "name": "wilkerson-frls-m16-series-compact-coalescing-filter"
            }
        ],
        "series": null,
        "specifications": {
            "Maximum Operating Pressure Metric": "10.3 Bar",
            "Maximum Operating Pressure": "150 PSIG",
            "Weight": "1.738 lb",
            "Break Quantity": "1",
            "Optional Package/Box Quantity": "1",
            "Temperature Range": "32°F to 125°F (0°C to 52°C)",
            "Flow": "46.1 SCFM",
            "Port": "1/2\"",
            "Applications": "For removal of extremely fine oil mists, oil aerosols and microscopic particles",
            "Available Options": "0.5 micron type B and 0.003 micron type D elements are optional",
            "Features": "Manual Drain Transparent Bowl and Guard 0.01 micron type C element 2.7 oz. bowl The differential pressure indicator changes from green to red with pressure loss",
            "Installation": "Can be installed in modular system",
            "Safety Notes": "FRL's are designed for air service only, unless otherwise indicated. A standard airline filter should be installed as a pre-filter when using a coalescing filter. SCFM ratings at 150 PSIG inlet pressure",
            "Use": "A standard airline filter should be installed as a pre-filter when using a coalescing filter.",
            "Prop 65 Warning": "WARNING : This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm."
        },
        "images": [
            {
                "src": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/images/b0/41/b041cc0802854ded479c9041bfb1cd1f58e73f189cf05a4fcd741f57b7c5cd12.webp",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/images/b0/41/b041cc0802854ded479c9041bfb1cd1f58e73f189cf05a4fcd741f57b7c5cd12.webp",
                "local_path": "dixonvalve/images/b0/41/b041cc0802854ded479c9041bfb1cd1f58e73f189cf05a4fcd741f57b7c5cd12.webp",
                "original_url": "https://dixonvalve.com/sites/default/files/styles/product/public/product/images/2017-09/1332874970wilkerson_coalescingfilter_m16-02a_color_pr_watermarked_0.jpg.webp",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "M16.pdf",
                "type": "pdf",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/pdfs/83/dd/83dd7cabcc49d6afe32d8db7925d3297c0a5ffb9e2032cf46dc25dae7185f5c2.pdf",
                "original_url": null,
                "local_path": "dixonvalve/pdfs/83/dd/83dd7cabcc49d6afe32d8db7925d3297c0a5ffb9e2032cf46dc25dae7185f5c2.pdf"
            },
            {
                "text": "M16.pdf",
                "type": "pdf",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/pdfs/3e/1d/3e1d059f4d995c313c81bfa4d07dcff294cac77cf1216e18d5b42ba1bbce5ec0.pdf",
                "original_url": null,
                "local_path": "dixonvalve/pdfs/3e/1d/3e1d059f4d995c313c81bfa4d07dcff294cac77cf1216e18d5b42ba1bbce5ec0.pdf"
            },
            {
                "text": "Wilkerson Filters, Regulators and Lubricators",
                "type": "pdf",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/pdfs/4c/15/4c15a0a63c2610ce4af6844491519a84dbf7929d4fedc94392b54c1e847448de.pdf",
                "original_url": null,
                "local_path": "dixonvalve/pdfs/4c/15/4c15a0a63c2610ce4af6844491519a84dbf7929d4fedc94392b54c1e847448de.pdf"
            },
            {
                "text": "DPL426_page 306.pdf",
                "type": "pdf",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/pdfs/f4/94/f494b1c3f98b847cc09727b90b71c4f4a11f22234537ab1a33b44853be82503b.pdf",
                "original_url": null,
                "local_path": "dixonvalve/pdfs/f4/94/f494b1c3f98b847cc09727b90b71c4f4a11f22234537ab1a33b44853be82503b.pdf"
            }
        ],
        "custom_fields": {
            "part_number": "M16-04M"
        },
        "description": "Manual Drain\n\n## Applications\n\nFor removal of extremely fine oil mists, oil aerosols and microscopic particles\n\n## Available Options\n\n0.5 micron type B and 0.003 micron type D elements are optional\n\n## Features\n\n- Manual Drain\n- Transparent Bowl and Guard\n- 0.01 micron type C element\n- 2.7 oz. bowl\n- The differential pressure indicator changes from green to red with pressure loss\n\n## Installation\n\nCan be installed in modular system\n\n## Safety Notes\n\n- FRL's are designed for air service only, unless otherwise indicated.\n- A standard airline filter should be installed as a pre-filter when using a coalescing filter.\n- SCFM ratings at 150 PSIG inlet pressure\n\n## Use\n\nA standard airline filter should be installed as a pre-filter when using a coalescing filter.\n\n## Prop 65 Warning\n\n**WARNING**: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.",
        "created_at": "2026-06-05 10:28:52",
        "variations": []
    }
}