{
    "data": {
        "id": 6763,
        "sku": "vent-lockr-safety-cam-groove-type-dp-dust-plug/l200-dp-ss",
        "name": "L200-DP-SS - Vent-Lock® Safety Cam & Groove Type DP Dust Plug",
        "type": "simple",
        "variations_count": 0,
        "manufacturer": "Dixon Valve",
        "product_url": "https://dixonvalve.com/en/products/vent-lockr-safety-cam-groove-type-dp-dust-plug/l200-dp-ss",
        "is_scraped": true,
        "price": null,
        "price_currency": "USD",
        "category": {
            "id": 74,
            "name": "vent-lockr-safety-cam-groove-type-dp-dust-plug"
        },
        "categories": [
            {
                "id": 74,
                "name": "vent-lockr-safety-cam-groove-type-dp-dust-plug"
            }
        ],
        "series": null,
        "specifications": {
            "Weight": "1.15 lb",
            "Break Quantity": "1",
            "Optional Package/Box Quantity": "1",
            "Size": "2\"",
            "Material": "316 Stainless Steel",
            "Applications": "Transfer of fluids and solids, with a safe disconnection",
            "Available Options": "Consult Dixon for availability of other materials",
            "Features": "Safety release cam and groove couplings permit the release of static pressure when disconnecting hose assemblies Venting system protects operator from being sprayed with hazardous or non-hazardous fluids or solids US Pat. 934759, CDN Pat. 277866",
            "Safety Notes": "Pressure rating recommendation is based on the use of mating Vent-Lock™ L-style fittings at ambient temperature 70°F (21°C) with standard Nitrile Rubber seal installed, for use at elevated temperature or other unusual operating conditions, consult Dixon. Does not interchange with standard cam and groove products use only with Vent-Lock™ L-style fittings.",
            "Prop 65 Warning": "WARNING : This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm."
        },
        "images": [
            {
                "src": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/images/ce/34/ce344570f9beac1d56f47333c9bd0993e00aee624a1211955d0bec7320668d22.webp",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/images/ce/34/ce344570f9beac1d56f47333c9bd0993e00aee624a1211955d0bec7320668d22.webp",
                "local_path": "dixonvalve/images/ce/34/ce344570f9beac1d56f47333c9bd0993e00aee624a1211955d0bec7320668d22.webp",
                "original_url": "https://dixonvalve.com/sites/default/files/styles/product/public/product/images/2017-09/vent%20lock%20dust%20plug%20type%20dp_l200-dp-ss_color_lg_watermarked.jpg.webp",
                "is_main": true
            }
        ],
        "pdf_documents": [
            {
                "text": "Vent-Lock Safety Cam and Groove Couplings",
                "type": "pdf",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/pdfs/5d/f8/5df86cade4ad6e1caa16a0b6d2893c65384461c92e21961d8a86da766b580562.pdf",
                "original_url": null,
                "local_path": "dixonvalve/pdfs/5d/f8/5df86cade4ad6e1caa16a0b6d2893c65384461c92e21961d8a86da766b580562.pdf"
            },
            {
                "text": "Petrochemical Life Cycle Exploration And Production",
                "type": "pdf",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/pdfs/c3/0c/c30c75e83523325f8bc95c839f8bad0dec90cc00bbd386db7597a6ba3082a123.pdf",
                "original_url": null,
                "local_path": "dixonvalve/pdfs/c3/0c/c30c75e83523325f8bc95c839f8bad0dec90cc00bbd386db7597a6ba3082a123.pdf"
            },
            {
                "text": "Cam & Groove Couplings and Accessories",
                "type": "pdf",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/pdfs/c6/88/c688a1ca59a4181aace994d6b3bfabe1756a51970ee5c28dbfbba24212a24a09.pdf",
                "original_url": null,
                "local_path": "dixonvalve/pdfs/c6/88/c688a1ca59a4181aace994d6b3bfabe1756a51970ee5c28dbfbba24212a24a09.pdf"
            },
            {
                "text": "L200-DP-SS",
                "type": "pdf",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/pdfs/d6/87/d68724fdbd4a2d2caf254dc1a8ba839235f8984444c999c7d3ab52bfb851d419.pdf",
                "original_url": null,
                "local_path": "dixonvalve/pdfs/d6/87/d68724fdbd4a2d2caf254dc1a8ba839235f8984444c999c7d3ab52bfb851d419.pdf"
            },
            {
                "text": "DPL426_page 187.pdf",
                "type": "pdf",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/pdfs/c6/05/c605e50bea3c30114e4f48e012601a4448585d3eae7ed328b835d9f8c7d857fd.pdf",
                "original_url": null,
                "local_path": "dixonvalve/pdfs/c6/05/c605e50bea3c30114e4f48e012601a4448585d3eae7ed328b835d9f8c7d857fd.pdf"
            },
            {
                "text": "DPL426_page 30.pdf",
                "type": "pdf",
                "url": "https://dixonvalve.weareindata.com/downloaded_assets/dixonvalve/pdfs/b0/9c/b09c8d76ca27cebd86c8cec1c4fd0e49b7c2ef2c6070de63f6d4b7618fa57e5f.pdf",
                "original_url": null,
                "local_path": "dixonvalve/pdfs/b0/9c/b09c8d76ca27cebd86c8cec1c4fd0e49b7c2ef2c6070de63f6d4b7618fa57e5f.pdf"
            }
        ],
        "custom_fields": {
            "part_number": "L200-DP-SS"
        },
        "description": "## Applications\n\nTransfer of fluids and solids, with a safe disconnection\n\n## Available Options\n\nConsult Dixon for availability of other materials\n\n## Features\n\n- Safety release cam and groove couplings permit the release of static pressure when disconnecting hose assemblies\n- Venting system protects operator from being sprayed with hazardous or non-hazardous fluids or solids\n- US Pat. 934759, CDN Pat. 277866\n\n## Safety Notes\n\n- Pressure rating recommendation is based on the use of mating Vent-Lock™ L-style fittings at ambient temperature 70°F (21°C) with standard Nitrile Rubber seal installed, for use at elevated temperature or other unusual operating conditions, consult Dixon.\n- Does not interchange with standard cam and groove products use only with Vent-Lock™ L-style fittings.\n\n## Prop 65 Warning\n\n**WARNING**: This product contains lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm.",
        "created_at": "2026-06-05 10:20:20",
        "variations": []
    }
}